DT-9054 RCD/GFCI TESTER
Professional Residual Current Device and Ground Fault Circuit Interrupter Tester
The DT-9054 is a professional RCD/GFCI tester designed for accurate testing of residual current devices and ground fault circuit interrupters. With fully programmed operation, digital readout of tripping parameters, and comprehensive testing capabilities, this instrument provides reliable verification of electrical protection device performance.
Key Features:
Advanced Testing Functions:
Fully programmed operation for simplified testing procedures
Accurate digital read out of tripping time and current
450ms readout for testing latest delay action breakers
Two LED lamps give quick check for correct wiring
Compact, lightweight and simple to operate design
Zero cross circuitry permits testing at 0° and 180° portion of sine wave
Comprehensive Testing Capabilities:
Trip current testing at multiple settings: 10mA, 30mA, 100mA, 300mA, 500mA, 650mA
Trip time measurement with 0-300ms range
Ramp test function: x0.4 to 1.1 times nominal rated current
Digital display of both trip time and trip current
Technical Specifications:
Electrical Specifications:
Operational voltage: 195V - 253V / 45 - 65Hz
Trip current settings: 10mA, 30mA, 100mA, 300mA, 500mA, 650mA
Trip current measurement accuracy: ±10% ±2 digits
Trip time ranges: 0ms – 300ms
Trip time accuracy: ±5% ±3 digits
Ramp test: x0.4 to 1.1 times nominal rated current, accuracy ±10%
Physical Specifications:
Size: 200mm x 70mm x 45mm (H x W x D)
Weight: 253g (lightweight and portable)
Testing Functions:
1. Standard Trip Testing:
Tests RCD/GFCI at preset current levels
Measures exact trip time in milliseconds
Verifies compliance with required trip times
Tests at both 0° and 180° points of AC waveform
2. Ramp Testing:
Gradually increases test current from 0.4x to 1.1x nominal rating
Determines actual trip current threshold
Identifies marginal protection device performance
Helps predict device condition and remaining life
3. Delay Action Testing:
Special 450ms testing mode for delay-type breakers
Tests S-type and selective RCDs
Verifies proper delayed tripping characteristics
Ensures compatibility with equipment having leakage current
4. Wiring Verification:
Two LED indicators for quick wiring check
Identifies correct phase-neutral-earth connections
Prevents testing on incorrectly wired circuits
Enhances testing safety and accuracy
Professional Applications:
RCD/GFCI Compliance Testing:
New installation verification and certification
Periodic inspection and testing requirements
Compliance with electrical safety standards
Documentation for regulatory compliance
Electrical Maintenance:
Preventive maintenance of protection devices
Troubleshooting nuisance tripping issues
Performance verification after electrical work
Quality control in electrical installations
Equipment Testing:
Testing of fixed RCD protection in distribution boards
Portable RCD adapter testing
GFCI receptacle verification
Equipment leakage protection assessment