DT-9056 DIGITAL EARTH LOOP TESTER
Professional Earth Loop Impedance and Circuit Analysis Instrument
The DT-9056 Digital Earth Loop Tester is a comprehensive electrical testing instrument designed for professional earth loop impedance measurement and circuit analysis. With True RMS measurement capability, backlit digital display, and multiple testing functions, this instrument provides accurate assessment of electrical circuit performance and safety device operation.
Key Features:
Advanced Display and Measurement:
Digital LCD display with backlit for clear visibility
Display update for voltage less than 2.5 times/second
Over-range indication on all functions for safety
ACV True RMS measurement for accurate voltage readings
Comprehensive Testing Functions:
Earth loop impedance measurement
GFCI trip time and current testing
EPD trip current measurement
Voltage drop percentage calculation
Line voltage and peak voltage measurement
Neutral-Ground voltage testing
Circuit frequency measurement
Technical Specifications:
Voltage Measurements:
Line voltage: 85.0~250.0 VAC, 0.1V resolution, ±1.0%rdg ±0.2dgtls accuracy
Peak line voltage: 121.0~354.0 VAC, 0.1V resolution, ±1.0%rdg ±0.2dgtls accuracy
Voltage loaded: 10.0~250.0 VAC, 0.1V resolution, ±2.5%rdg ±0.2dgtls accuracy
Neutral-Ground Voltage: 0.0~10.0 VAC, 0.1V resolution, ±2.5%rdg ±0.2dgtls accuracy
Circuit Analysis Functions:
Frequency: 45.0~65.0 Hz, 0.1Hz resolution, ±1.0%rdg ±0.2dgtls accuracy
%Voltage drop: 0.1%~99.9%, 0.1% resolution, ±2.5%rdg ±0.2dgtls accuracy
Impedance Measurement:
Impedance-Hot neutral & Ground: 0.000Ω~3.00Ω (>3Ω indication)
Resolution: 0.01Ω
Accuracy: ±2.5%rdg ±0.02dgtls
Safety Device Testing:
GFCI Trip Time: 1ms to 6.5ms counter, 1ms resolution, ±1.0%rdg ±2ms accuracy
GFCI Trip Current: 6.0~9.0mA, 0.1mA resolution, ±1.0%rdg ±2mA accuracy
EPD Trip Current: 30.0~37.0mA, 0.1mA resolution, ±1.0%rdg ±2mA accuracy
Physical Specifications:
Size: 195mm x 70mm x 48mm (H x W x D)
Weight: 415g
Safety & Compliance:
CE Certified
Safety Standard: EN 61010-1 CAT III 600V
EMC & LVD Standards:
EN 61326
EN 61010-1
EN 61010-02-032
EN 61010-02-033
Professional Applications:
Earth Loop Impedance Testing:
Measurement of earth fault loop impedance
Verification of circuit protective device coordination
Assessment of earth connection effectiveness
Compliance testing of electrical installations
GFCI/EPD Device Testing:
Ground fault circuit interrupter performance testing
Equipment protection device verification
Trip time and current measurement
Safety device compliance assessment
Circuit Performance Analysis:
Voltage drop measurement under load conditions
Line voltage quality assessment
Neutral-ground potential difference checking
Circuit frequency verification
Peak voltage measurement